OTR MFI18 Trinseo PULSE 2000 EZ

Nombre del producto: OTR – MFI18 – TRINSEO – PULSE 2000 EZ
Categoría: Otros
Información del manual del producto: Technical Information
PULSE™ 2000 EZ
PC/ABS Engineering Resin
Overview
Overview
PULSE™ 2000EZ is a high-heat PC/ABS resin delivering optimized performance for automotive interior component
applications.

Benefits
• Easy flow, reduced scrap, and faster cycle times, while enabling thin wall part design for mass reduction.
• High-impact strength even at low temperature
• High Heat resistance for demanding automotive interior components
• Consistent natural white color produces high quality part appearance when used with color concentrates (self
coloring) or Trinseo Color Masterbatch Technology
• Low odor & VOC to meet all global Automotive OEM specifications

Applications:
• Mid (floor)consoles
• Instrument Panel components
• Door panel trim
• Pillars
• Storage / load floors / glove box
Automotive Specifications
• 3M 11-0003-5762-1
• BMW GS 93016
• CHRYSLER MS-DB-195 CPN 2967
• CHRYSLER MS-DB-195 CPN 3159
• CHRYSLER MS-DB-195 CPN 3401
• CHRYSLER MS-DB-195 CPN 3408
• CHRYSLER MS-DB-195 CPN 4598
• CHRYSLER MS-DB-195 CPN 506
• DAIMLER DBL 5404.28
• DAIMLER DBL 5404.29
• FORD WSS-M4D585-C1
• GM GMW15581P-ABS+PC-T3
• GM GMW15581P-ABS+PC-T6
• RNPO AS33
• TESLA TM-1003 10/20
• TOYOTA TSM 5526G-1
• TOYOTA TSM 5526G-2
• VOLKSWAGEN TL 522 31
• VOLKSWAGEN TL 522 31-A
• VOLKSWAGEN TL 522 31-B
Physical
Nominal Value (English)
Nominal Value (SI)
Test Method
Density
1.13 g/cm³
1.13 g/cm³
ISO 1183
Apparent (Bulk) Density
0.66 g/cm³
0.66 g/cm³
ISO 60
Melt Mass-Flow Rate (MFR) (260°C/5.0 kg)
18 g/10 min
18 g/10 min
ISO 1133
Spiral Flow 1
18.5 in
47.0 cm

Molding Shrinkage
4.0E-3 to 7.0E-3 in/in
0.40 to 0.70 %
ISO 294-4
Mechanical
Nominal Value (English)
Nominal Value (SI)
Test Method
Tensile Modulus
348000 psi
2400 MPa
ISO 527-1/1
Tensile Stress (Yield)
7400 psi
51.0 MPa
ISO 527-2/50
Tensile Strain (Break)
120 %
120 %
ISO 527-2/50
Flexural Modulus 2
334000 psi
2300 MPa
ISO 178
Impact
Nominal Value (English)
Nominal Value (SI)
Test Method
Charpy Notched Impact Strength
ISO 179/1eA
-22°F (-30°C)
12 ft·lb/in²
25 kJ/m²
73°F (23°C)
24 ft·lb/in²
50 kJ/m²
Page: 1 of 3
Form No. 500-00050202en
Thermal
Nominal Value (English)
Nominal Value (SI)
Test Method
Deflection Temperature Under Load
ISO 75-2/A
264 psi (1.8 MPa), Unannealed
223 °F
106 °C
Vicat Softening Temperature
262 °F
128 °C
ISO 306/B50
CLTE – Flow (-22 to 176°F (-30 to 80°C))
4.2E-5 in/in/°F
7.5E-5 cm/cm/°C
ISO 11359-2
Injection
Nominal Value (English)
Nominal Value (SI)
Drying Temperature
212 °F
100 °C

Drying Time
4.0 hr
4.0 hr

Processing (Melt) Temp
491 to 554 °F
255 to 290 °C

Mold Temperature
140 to 176 °F
60 to 80 °C

Notes
These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests.
1 Melt Temperature: 500°F (260°C), Injection Pressure: 2.61E+4 psi (1.80E+3 bar)
2 0.079 in/min (2.0 mm/min)
Page: 2 of 3
Form No. 500-00050202en
Technical Information
trinseo.com
The principles of Responsible Care® and sustainability influence the production of
printed literature for Trinseo PLC and its affiliated companies. As a contribution
towards the protection of our environments, Trinseo’s printed literature is produced in
small quantities and on paper containing recovered/post-consumer fiber and using 100
percent soy-based ink whenever possible.
Product Stewardship
Trinseo and its affiliated companies have a fundamental concern for all who make,
distribute, and use their products and for the environment in which we live. This
concern is the basis for our Product Stewardship philosophy by which we assess the
safety, health, and environmental information on our products so that appropriate steps
may be taken to protect employee and public health and our environment. The
success of our product stewardship program rests with each and every individual
involved with Trinseo products – from the initial concept and research, to manufacture,
use, sale, disposal, and recycle of each product.
Customer Notice
Customers are responsible for reviewing their manufacturing processes and their
applications of Trinseo products from the standpoint of human health and
environmental quality to ensure that Trinseo products are not used in ways for which
they are not suitable. Trinseo personnel are available to answer questions and to
provide reasonable technical support. Trinseo product literature, including safety data
sheets, should be consulted prior to the use of Trinseo products. Current safety data
sheets are available from Trinseo.
No freedom from infringement of any patent owned by Trinseo or others is to be
inferred. Because use conditions and applicable laws may differ from one location to
another and may change with time, the customer is responsible for determining
whether products and the information in this document are appropriate for the
customer’s use and for ensuring that the customer’s workplace and disposal practices
are in compliance with applicable legal requirements. Although the information herein
is provided in good faith and was believed to be accurate when prepared, Trinseo
assumes no obligation or liability for the information in this document.
NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS
TRINSEO REQUESTS THAT CUSTOMERS REFER TO TRINSEO’S MEDICAL
APPLICATION POLICY HTTP://WWW.TRINSEO.COM/MEDICAL.HTM BEFORE
CONSIDERING THE USE OF TRINSEO PRODUCTS IN MEDICAL APPLICATIONS.
THE RESTRICTIONS AND DISCLAIMERS SET FORTH IN THAT POLICY ARE
INCORPORATED BY REFERENCE.
For more information on products, innovations, expertise, and other services available
from Trinseo, visit www.trinseo.com, or in the U.S. contact us at +1-855-TRINSEO
(+1-855-874-6736).
DISCLAIMER
TRINSEO MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, IN
THIS DOCUMENT; ALL IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE (INCLUDING MEDICAL
APPLICATIONS) ARE EXPRESSLY EXCLUDED. SINCE THE CONDITIONS
AND METHODS OF USE OF THE INFORMATION AND PRODUCTS
REFERRED TO ARE BEYOND TRINSEO’S KNOWLEDGE AND CONTROL,
TRINSEO DISCLAIMS ANY AND ALL LIABILITY FOR LOSSES OR
DAMAGES THAT MAY RESULT FROM RELIANCE ON THE INFORMATION
OR USE OF THE PRODUCTS DESCRIBED HEREIN. TRINSEO MAKES NO
WARRANTIES, EXPRESS OR IMPLIED, THAT THE USE OF ANY
TRINSEO PRODUCT WILL BE FREE FROM ANY INFRINGEMENT
CLAIMS.
GENERAL NOTICE
Any photographs of end-use applications in this document represent potential
end-use applications but do not necessarily represent current commercial
applications, nor do they represent an endorsement by Trinseo of the actual
products. Further, these photographs are for illustration purposes only and do
not reflect either an endorsement or sponsorship of any other manufacturer
for a specific potential end-use product or application, or for Trinseo, or for
specific products manufactured by Trinseo.If products are described as
“experimental” or “developmental”: (1) product specifications may not be fully
determined; (2) analysis of hazards and caution in handling and use are
required; (3) there is greater potential for Trinseo to change specifications
and/or discontinue production, and (4) although Trinseo may from time to
time provide samples of such products, Trinseo is not obligated to supply or
otherwise commercialize such products for any use or application
whatsoever.
For additional information not covered by the content of this document or to
ensure you have the latest version of this document available, please refer to
our website at www.trinseo.com/contact.
Follow us at:
Copyright ©Trinseo (2024) All rights reserved.
™Trademark of Trinseo S.A. or its affiliates
®Responsible Care is a service mark of the American
Chemistry Council
Page: 3 of 3
Form No. 500-00050202en