Resina Polietileno HDPE DMDA-8940 NT 7 Dow
Nombre del producto: HDPE DMDA-8940 NT 7
Categoría: Polietileno
Información del manual del producto: Technical Data Sheet
DOW™ HDPE DMDA-8940 NT 7 High Density
Polyethylene Resin
®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
Page 1 of 3
DOW™ HDPE DMDA-8940 NT 7 High Density Polyethylene Resin
Form No. 400-00071343en-0823 S2D
Description
DOW™ DMDA-8940 NT 7 High Density Polyethylene (HDPE) Resin is produced via
UNIPOL™ Process Technology from Dow and is intended for use in a broad range of
injection molding applications such as housewares, toys, food containers and pails. This
resin has been designed to provide an excellent balance of toughness, environmental stress
crack resistance and processability.
Main
Characteristics
•
Injection molding
•
For injection molded housewares, toys, food containers and pails
•
Excellent balance of toughness, stress crack resistance and processability
•
Very narrow molecular weight distribution
Complies with
•
U.S. FDA 21 CFR 177.1520(c)3.2a
•
U.S. FDA -DMF
•
Canadian HPFB No Objection
•
EU, No 10/2011
Consult the regulations for complete details.
Additive
•
Antiblock: No
•
Processing Aid: No
•
Slip: No
Properties1
Physical
Nominal Value
(English)
Nominal Value
(SI)
Test Method2
Density
0.951
g/cm3
0.951
g/cm3
ASTM D792
Melt Index (190ºC/2.16 kg)
44
g/10min
44
g/10min
ASTM D1238
Mechanical
Tensile Strength
Yield
Break
3900
3900
Psi
Psi
26.9
26.9
MPa
MPa
ASTM 638
Tensile Elongation
Yield
Break
5.0
10
%
%
5.0
10
%
%
ASTM 638
Flexural Modulus – 2% Secant
148000
Psi
1020
MPa
ASTM D790B
1.
Typical properties: these are not to be construed as specifications. Users should confirm results by their own tests.
2.
ASTM: American Society for Testing and Materials
®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
Page 2 of 3
DOW™ HDPE DMDA-8940 NT 7 High Density Polyethylene Resin
Form No. 400-00071343en-0823 S2D
Properties (Cont.)
Impact
Nominal Value
(English)
Nominal Value
(SI)
Test Method
Tensile Impact Strength3
40.0
ft-lb/in2
84.1
kJ/m2
ASTM D1822
Hardness
Durometer Hardness (Shore D)
64
64
ASTM D2240
Thermal
Deflection Temperature Under
Load
66 psi (0.45 MPa), Unannealed
160
°F
71.1
°C
ASTM D648
Brittleness Temperature
-98.0
ºF
-72.2
°C
ASTM D746
Vicat Softening Temperature
253
ºF
123
°C
ASTM D1525
Melting Temperature (DSC)
262
ºF
128
°C
Internal Method
Peak Crystallization Temperature
(DSC)
241
ºF
116
°C
Internal Method
Additional Information
Plaque molded and tested in accordance with ASTM D4976
3.
Type S
Product
Stewardship
The Dow Chemical Company and its subsidiaries («Dow») has a fundamental concern for all
who make, distribute, and use its products, and for the environment in which we live. This
concern is the basis for our Product Stewardship philosophy by which we assess the safety,
health, and environmental information on our products and then take appropriate steps to
protect employee and public health and our environment. The success of our Product
Stewardship program rests with each and every individual involved with Dow products —
from the initial concept and research, to manufacture, use, sale, disposal, and recycle of
each product.
Customer Notice
Dow strongly encourages its customers to review both their manufacturing processes and
their applications of Dow products from the standpoint of human health and environmental
quality to ensure that Dow products are not used in ways for which they are not intended or
tested. Dow personnel are available to answer your questions and to provide reasonable
technical support. Dow product literature, including safety data sheets, should be consulted
prior to use of Dow products. Current safety data sheets are available from Dow.
Medical
Applications
Policy
Any and all medical application use of Dow materials, whether a device, a component, or
any type of primary or secondary packaging of a medically related object or substance,
needs to be reviewed and approved by Dow before any Dow material can be tested in such
application.
Dow requests that customers considering use of Dow products in medical applications notify
Dow so that appropriate assessments may be conducted. Dow does not endorse or claim
suitability of its products for specific medical applications. It is the responsibility of the
medical device or pharmaceutical manufacturer to determine that the Dow product is safe,
lawful, and technically suitable for the intended use. DOW MAKES NO WARRANTIES,
EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW PRODUCT
FOR USE IN MEDICAL APPLICATIONS.
For further information contact your Dow sales or technical representative to request a
Medical Application Review Request Form.
®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow
Page 3 of 3
DOW™ HDPE DMDA-8940 NT 7 High Density Polyethylene Resin
Form No. 400-00071343en-0823 S2D
Medical
Applications
Policy (Cont.)
Additional details of Dow’s Medical Applications Policy are available at:
https://www.dow.com/en-us/support/product-safety.html
Tobacco and
Marijuana Policy
Dow does not support or intend for its products to be used, directly or indirectly, in the
production of tobacco, the manufacture of tobacco products, the manufacture and use of
electronic cigarettes (including vaping devices), the production of marijuana, or the
manufacture of marijuana products intended for human consumption, where the Dow
product (or its residues) may be present in the finished product or be alleged to facilitate the
delivery of nicotine, other tobacco components, marijuana, or marijuana components.
Harmful
Applications
Policy
Dow does not intend for its products to be used in applications specifically intended to harm
humans.
Contact:
www.dow.com/contact
NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and
applicable laws may differ from one location to another and may change with time, the Customer is responsible for determining
whether products and the information in this document are appropriate for the Customer’s use and for ensuring that the
Customer’s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Dow
assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
NOTICE: If products are described as «experimental» or «developmental»: (1) product specifications may not be fully
determined; (2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for Dow to
change specifications and/or discontinue production; and (4) although Dow may from time to time provide samples of such
products, Dow is not obligated to supply or otherwise commercialize such products for any use or application whatsoever.
NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled laboratory testing. They
are offered in good faith, but without guarantee, as conditions and method of use of Dow products are beyond Dow’s control.
Dow recommends that the prospective user determine the suitability of these materials and suggestions before adopting them
on a commercial scale.
To the best of our knowledge, the information contained herein is accurate and reliable as of the date of publication, however
we do not assume any liability for the accuracy and completeness of such information.
For additional information, not covered by the content of this document, contact us via our web site
http://www.dow.com/products_services/.
This document is intended for use within Europe, Middle East and Africa.