Polietileno de Alta Densidad PRIMATOP 200952 Amco Polymers
Nombre del producto: PE – HDPE – MFI20 – AMCO – PRIMATOP 200952
Categoría: Polietileno
Información del manual del producto: PRIMATOP®HDPE 200952
Amco Polymers – High Density Polyethylene
Tuesday, October 10, 2023
General Information
General
Material Status
• Commercial: Active
Availability
• North America
Agency Ratings
• FDA 21 CFR 177.1520
Processing Method
• Injection Molding
ASTM & ISO Properties 1
Physical
Nominal Value Unit
Test Method
Density
0.952 g/cm³
ASTM D1505
Melt Mass-Flow Rate (MFR) (190°C/2.16 kg)
20 g/10 min
ASTM D1238
Mechanical
Nominal Value Unit
Test Method
Tensile Strength (Yield)
3600 psi
ASTM D638
Tensile Elongation (Break)
300 %
ASTM D638
Flexural Modulus – 3% Secant
140000 psi
ASTM D790
Thermal
Nominal Value Unit
Test Method
Brittleness Temperature
< -95.0 °F
ASTM D746
Vicat Softening Temperature
252 °F
ASTM D1525
Notes
1 Typical properties: these are not to be construed as specifications.
Amco Polymers disclaimer statement: The technical information, suggested uses, and applications presented, are made without charge and are believed to be reliable; however, Amco Polymers disclaims
responsibility for reliance on, and results of use of, this information. The data listed herein falls within the nominal range of product properties but should not be used to establish specification limits or used
alone as a basis for design. This information is not intended as a warranty of any kind. Users must make their own representative test and assume all risks of use, whether the product is used alone or in
combination with other materials. Amco Polymers assumes no obligation or liability for any advice furnished or results obtained with respect to the product, nor for use of the product in infringement of any
patent. ALL WARRANTIES, EXPRESSED OR IMPLIED, OF MERCHANTABILITY, AND FITNESS FOR A PARTICULAR PURPOSE OR USE ARE EXCLUDED AND DISCLAIMED. The foregoing
limitation
of remedy and exclusion of liability is reflected in, and is part of, the consideration for the price charged for the product.
All data displayed herein has been obtained via testing of injected molded specimens of natural color. Pigmentation may affect certain properties to various degrees.
¹ Shrinkage data are general guidelines and are only intended to allow comparison to other materials. They should not be used as the sole source of information for generating core and cavity mold
dimensions.
Page: 1 of 1