PP-DMDD 6200 NT 7-DOW

Nombre del producto: PP-DMDD 6200 NT 7-DOW
Categoría: Polietileno
Información del manual del producto: Technical Information
UNIVAL™ DMDD-6200 NT 7
High Density Polyethylene Resin 
Page: 1 of 2
® ™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow.
Form No. 400-00070258en
Rev: 2011-10-04
Overview
• Excellent stress crack resistance and rigidity
• High impact strength
• Moderate swell
• High melt strength
• Complies with:
• U.S. FDA 21 CFR 177.1520 (c) 3.2a
• EU, No 10/2011
• CANADIAN HPFB NO OBJECTION (WITH LIMITATIONS)
• Consult the regulations for complete details.
 
UNIVAL™DMDD-6200 NT 7 High Density Polyethylene (HDPE) Resin is a multi-purpose polymer designed for high
speed production of blow molded containers used to package food products, household industrial chemicals (e.g.,
detergents, bleach, fabric softeners), toiletries and cosmetics (e.g., shampoos, creams, lotions, etc.), health and
medicinal aids. In addition, this product can be blow molded into other thin walled parts and houseware items, and also
can be extruded into profiles.
Additive
• Antiblock: No
• Slip: No
• Processing Aid: No
Physical
Nominal Value (English)
Nominal Value (SI)
Test Method
Density
0.953 g/cm³
0.953 g/cm³
ASTM D792
Melt Index
ASTM D1238
190°C/2.16 kg
0.25 g/10 min
0.25 g/10 min
190°C/21.6 kg
23 g/10 min
23 g/10 min
Environmental Stress-Cracking Resistance
(ESCR)
ASTM D1693
122°F (50°C), 100% Igepal, F50
50.0 hr
50.0 hr
Mechanical
Nominal Value (English)
Nominal Value (SI)
Test Method
Tensile Strength
ASTM D638
Yield
3800 psi
26.2 MPa
Break
3700 psi
25.5 MPa
Tensile Elongation
ASTM D638
Yield
6.0 %
6.0 %
Break
900 %
900 %
Flexural Modulus – 2% Secant
148000 psi
1020 MPa
ASTM D790B
Impact
Nominal Value (English)
Nominal Value (SI)
Test Method
Tensile Impact Strength 1
100 ft·lb/in²
210 kJ/m²
ASTM D1822
Hardness
Nominal Value (English)
Nominal Value (SI)
Test Method
Durometer Hardness (Shore D)
59  
59  
ASTM D2240
Thermal
Nominal Value (English)
Nominal Value (SI)
Test Method
Deflection Temperature Under Load
ASTM D648
66 psi (0.45 MPa), Unannealed
158 °F
70.0 °C
Brittleness Temperature
< -105 °F < -76.1 °C ASTM D746 Vicat Softening Temperature 264 °F 129 °C ASTM D1525 Melting Temperature (DSC) 270 °F 132 °C Dow Method Peak Crystallization Temperature (DSC) 246 °F 119 °C Dow Method Additional Information Plaque molded and tested in accordance with ASTM D3976. Notes   These are typical properties only and are not to be construed as specifications. Users should confirm results by their own tests. 1 Type S Page: 2 of 2 ® ™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow. Form No. 400-00070258en Rev: 2011-10-04 Product Stewardship The Dow Chemical Company and its subsidiaries (“Dow”) has a fundamental concern for all who make, distribute, and use its products, and for the environment in which we live. This concern is the basis for our Product Stewardship philosophy by which we assess the safety, health, and environmental information on our products and then take appropriate steps to protect employee and public health and our environment. The success of our Product Stewardship program rests with each and every individual involved with Dow products ─from the initial concept and research, to manufacture, use, sale, disposal, and recycle of each product. Customer Notice Dow strongly encourages its customers to review both their manufacturing processes and their applications of Dow products from the standpoint of human health and environmental quality to ensure that Dow products are not used in ways for which they are not intended or tested. Dow personnel are available to answer your questions and to provide reasonable technical support. Dow product literature, including safety data sheets, should be consulted prior to use of Dow products. Current safety data sheets are available from Dow. Medical Applications Policy NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow will not knowingly sell or sample any product or service (“Product”) into any commercial or developmental application that is intended for: a. long-term or permanent contact with internal bodily fluids or tissues. “Long-term” is contact which exceeds 72 continuous hours; b. use in cardiac prosthetic devices regardless of the length of time involved (“cardiac prosthetic devices” include, but are not limited to, pacemaker leads and devices, artificial hearts, heart valves, intra-aortic balloons and control systems, and ventricular bypass-assisted devices); c. use as a critical component in medical devices that support or sustain human life; or d. use specifically by pregnant women or in applications designed specifically to promote or interfere with human reproduction. Dow requests that customers considering use of Dow products in medical applications notify Dow so that appropriate assessments may be conducted. Dow does not endorse or claim suitability of its products for specific medical applications. It is the responsibility of the medical device or pharmaceutical manufacturer to determine that the Dow product is safe, lawful, and technically suitable for the intended use. DOW MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW PRODUCT FOR USE IN MEDICAL APPLICATIONS. Disclaimer NOTICE: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, the Customer is responsible for determining whether products and the information in this document are appropriate for the Customer’s use and for ensuring that the Customer’s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Dow assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. NOTICE: If products are described as “experimental” or “developmental”: (1) product specifications may not be fully determined; (2) analysis of hazards and caution in handling and use are required; (3) there is greater potential for Dow to change specifications and/or discontinue production; and (4) although Dow may from time to time provide samples of such products, Dow is not obligated to supply or otherwise commercialize such products for any use or application whatsoever. NOTICE: This data is based on information Dow believes to be reliable, as demonstrated in controlled laboratory testing. They are offered in good faith, but without guarantee, as conditions and method of use of Dow products are beyond Dow’s control. Dow recommends that the prospective user determine the suitability of these materials and suggestions before adopting them on a commercial scale. To the best of our knowledge, the information contained herein is accurate and reliable as of the date of publication, however we do not assume any liability for the accuracy and completeness of such information. Additional Information North America Europe/Middle East +800-3694-6367 U.S. & Canada: 1-800-441-4369 +31-11567-2626 1-989-832-1426 Italy: +800-783-825 Mexico: +1-800-441-4369   Latin America South Africa +800-99-5078 Argentina: +54-11-4319-0100 Brazil: +55-11-5188-9000 Colombia: +57-1-219-6000 Asia Pacific +800-7776-7776 Mexico: +52-55-5201-4700 +603-7965-5392 www.dowplastics.com This document is intended for use within Asia Pacific, Latin America, North America Published: 2003-10-10 © 2019 The Dow Chemical Company